On June 14, 2017

State announces “Red Tag” rule for aboveground storage tanks

The Vermont Agency of Natural Resources, June 8, filed a new rule for aboveground storage tanks that will require inspectors to affix red tags on heating oil tanks that are at imminent risk of a fuel spill. Fuel distributors are not allowed to deliver fuel to a red-tagged tank until the tank has been repaired or replaced. Homeowners will have until July 31, 2020, to schedule their first inspection and after the first inspection must have their tanks inspected once every three years.

The red-tag rule will help prevent costly spills of heating oil from aboveground storage tanks. Last year, Vermont’s Petroleum Cleanup Fund spent over $1 million providing assistance to tank owners for tank upgrades and repairs and paying for cleanups associated with roughly 80 aboveground storage tank releases. The Petroleum Cleanup Fund’s heating oil account is financed through a one-cent fee on each gallon of heating oil fuel.

“Preventing fuel spills that contaminate the environment and put human health at risk is much more cost-effective than cleanup,” said Emily Boedecker, Commissioner of the Vermont Department of Environmental Conservation. “Red-tag inspections will reduce the frequency of unintended releases, improve environmental outcomes and reduce the need for expensive cleanups.”

Vermont spends on average $700,000 a year to clean up aboveground storage tank fuel spills, most of which are avoidable. Homeowners whose heating oil tanks are red-tagged may be eligible for up to $2,000 to replace indoor tanks and up to $3,000 for outdoor tanks.  To apply for assistance, individuals may contact [email protected].

The following five conditions are considered unsafe and will result in a red tag:

Unstable foundation;

Uncoated or un-sleeved piping from the tank to the heating appliance, which could corrode if in contact with soil or concrete and cause a release;

Unequal fill and vent pipe size, which could lead to over-pressurization of the system;

No vent whistle, which could lead to an overfill of a tank because the person delivering fuel cannot be sure when the tank is approaching capacity; and

Poor tank condition such as excessive rust, leaks, weeps, drips. These are all signs that a tank needs to be replaced.

Do you want to submit feedback to the editor?

Send Us An Email!

Related Posts

Two members, including chair, resign from the Commission on the Future of Public Education in Vermont

June 25, 2025
By Corey McDonald/VTDigger Two members of the Commission on the Future of Public Education in Vermont, including the commission’s chair, announced last week they would be resigning, saying they no longer believed their efforts would make any impact. Meagan Roy, the chair of the commission, and Nicole Mace, the former representative of the Vermont School Boards…

Vt plastic bag use dropped 91% following ban, researchers find

June 25, 2025
In the midst of 2020 Covid measures, another change took place in Vermont: A law went into effect banning businesses from offering plastic bags to customers, with paper bags only available for a fee. A 2023 analysis of a survey of hundreds of Vermonters found the law appeared to have worked. Plastic bag use in…

A Roadmap

June 25, 2025
The Vermont Legislature adjourned Monday evening, June 16, following the passage of H.454, the education reform plan. I call it a roadmap as the legislation lays out a list of changes that will take place over the next few years. And as various studies and reports come back in, there will also likely be adjustments,…

Vermont to get over $21 million in nationwide settlement with Purdue Pharma and the Sacklers

June 25, 2025
Attorney General Charity Clark announced June 16 that all 55 attorneys general, representing all eligible states and U.S. territories, have agreed to sign on to a $7.4 billion settlement with Purdue Pharma and its owners, the Sackler family. This settlement was reached after the previous settlement was rejected by the U.S. Supreme Court. It resolves…